DIMENSIONS AND ALLOWABLE OPERATIONAL MOVEMENT
Normal Pipe Size (in) |
1.25 | 1.5 | 2 | 2.5 | 3 | 4 | 5 | 6 | 8 | 10 | 12 | 14 | 16 | 18 | 20 | 24 |
| |
| | | | | | | | | | | | | | | |
| Neutral Length (in) |
7 | 7 | 7 | 7 | 7 | 9 | 9 | 9 | 13 | 13 | 13 | 13.75 | 13.75 | 13.75 | 13.75 | 13.75 |
| |
| | | | | | | | | | | | | | | |
Axial Compression (in) |
2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2.36 | 2.36 | 2.36 | 2.36 | 2.36 | 2.36 | 2.36 | 2.36 |
| |
| | | | | | | | | | | | | | | |
Axial Elongation (in) |
1.18 | 1.18 | 1.18 | 1.18 | 1.18 | 1.38 | 1.38 | 1.38 | 1.38 | 1.38 | 1.38 | 1.38 | 1.38 | 1.38 | 1.38 | 1.38 |
| |
| | | | | | | | | | | | | | | |
Lateral Deflection (in) |
1.77 | 1.77 | 1.77 | 1.77 | 1.77 | 1.58 | 1.58 | 1.58 | 1.38 | 1.38 | 1.38 | 1.38 | 1.38 | 1.38 | 1.38 | 1.38 |
| |
| | | | | | | | | | | | | | | |
Angular Deflection (DEG) |
40 | 40 | 40 | 40 | 40 | 35 | 35 | 35 | 30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 |
Deflection Summary:
|
Compression
 |
Elongation
 |
Lateral
 |
Angular
 |
|
| |
| |
|
| OPERATING CONDITIONS |
| |
Working Pressure (PSI) |
225 | 225 | 225 | 225 | 225 | 225 | 225 | 225 | 225 | 225 | 225 | 142 | 142 | 125 | 125 | 125 |
| |
| | | | | | | | | | | | | | | |
Burst Pressure (PSI) |
855 | 855 | 855 | 855 | 855 | 855 | 855 | 855 | 855 | 855 | 855 | 340 | 340 | 340 | 340 | 340 |
| |
| | | | | | | | | | | | | | | |
Working Temperature (DEG F) |
220 | 220 | 220 | 220 | 220 | 220 | 220 | 220 | 220 | 220 | 220 | 220 | 220 | 220 | 220 | 220 |
| |
| | | | | | | | | | | | | | | |
Vacuum Rating (in HG) |
26 | 26 | 26 | 26 | 26 | 26 | 26 | 26 | 26 | 26 | 26 | 26 | 26 | 26 | 26 | 26 |
| |
| |
|
| TYPICAL APPLICATIONS AND FLUIDS |
APPLICABLE FLUIDS:
Water, Warm Water, Sea Water, Weak Acids, Air
|
TYPICAL APPLICATIONS:
Pumps (Suction & Discharge Line) Air Conditioning, Ventilating, Chiller, Condenser Piping System, Sanitary, Irrigation Systems, Fire Fighting Systems, Hosereel Piping System, Marine Air Intake On Diesel Engines, Ballast Line
|
AVAILABLE FLANGE STANDARDS:
ANSI, BS10, BS4504, DIN, JIS AND SPECIAL SPECIFICATION (PLEASE REFER TO TABLE 4)
|
NOTES:
- Joints working under higher temperatures have a proportionally reduced pressure rating.
- Pressures shown are recommended operating pressures. Test pressure is 1.5 times "operating".
- Vacuum
Rating (in HG) is based on neutral installed length, without external load. Products should not be installed "elongated" on vacuum applications. AFA Style 99TFA expansion joints are furnished complete with retaining flanges.
- Because of storage space and shipping methods the (L) length of the joints mat vary from the dimension (L) above. This variance has no effect on the performance of the product. If the joint has been compressed or extended both can be manually extended and compressed to fit the measure space.
- Size 700mm (28°) is available on your request.
|
|
Model 99TUA
|
|
DIMENSIONS AND ALLOWABLE OPERATIONAL MOVEMENT
Normal Pipe Size (in) |
0.75 | 1 | 1.25 | 1.5 | 2 | 2.5 | 3 |
| |
| | | | | | |
| Neutral Length (in) |
8 | 8 | 8 | 8 | 8 | 8 | 8 |
| |
| | | | | | |
Axial Compression (in) |
0.875 | 0.875 | 0.875 | 0.875 | 0.875 | 0.875 | 0.875 |
| |
| | | | | | |
Axial Elongation (in) |
0.25 | 0.25 | 0.25 | 0.25 | 0.25 | 0.25 | 0.25 |
| |
| | | | | | |
Lateral Deflection (in) |
0.875 | 0.875 | 0.875 | 0.875 | 0.875 | 0.875 | 0.875 |
| |
| | | | | | |
Angular Deflection (DEG) |
45 | 45 | 45 | 45 | 45 | 45 | 45 |
Deflection Summary:
|
Compression
 |
Elongation
 |
Lateral
 |
Angular
 |
|
| |
| |
|
| OPERATING CONDITIONS |
| |
Working Pressure (PSI) |
150 | 150 | 150 | 150 | 150 | 150 | 150 |
| |
| | | | | | |
Burst Pressure (PSI) |
710 | 710 | 710 | 710 | 710 | 710 | 710 |
| |
| | | | | | |
Working Temperature (DEG F) |
220 | 220 | 220 | 220 | 220 | 220 | 220 |
| |
| | | | | | |
Vacuum Rating (in HG) |
16 | 16 | 16 | 16 | 16 | 16 | 16 |
| |
| |
|
| TYPICAL APPLICATIONS AND FLUIDS |
APPLICABLE FLUIDS:
Water, Warm Water, Sea Water, Weak Acids, Air
|
TYPICAL APPLICATIONS:
Pumps (Suction & Discharge Line) Air Conditioning, Ventilating, Chiller, Condenser Piping System, Sanitary, Irrigation Systems, Fire Fighting Systems, Hosereel Piping System, Marine Air Intake On Diesel Engines, Ballast Line
|
UNION THREADED AVAILABILITY:
NPT
|
NOTES:
- Joints working under higher temperatures the pressure rating is reduced accordingly.
- Pressures shown are recommended "operating". Test pressure is 1.5 times "operating".
- Vacuum
Rating (in HG) is based on neutral installed length, without external load. Products should not be installed "elongated" on vacuum applications.
- AFA Style 99TUA expansion joints are furnished completed with threaded unions.
- Because of storage space and shipping methods the (L) length of the joints mat vary from the dimension (L) above. This variance has no effect on the performance of the product. Eventually, if the joint have been compressed or extended both can be manually extend and compressed to fit the measure space.
- AFA Style 99SFA permisible movements are shown in (Table 1A).
|
|
|
Model 99TFA | Model 99TUA
|
|
|
625 Hollywood Avenue Cherry Hill, NJ 08002-2822 Phone: 856.486.7550 Fax: 856.486.7551
|
|
About SISCO Manufacturing |
Warranty Information |
Contact SISCO
|
|
Copyright 2003 by Sisco Manufacturing Company, Inc.
Site Design by Cerulean Diversified Services
|
|